(1) Motion Picture Theater. (a) It would be desirable to provide panic bar hardware on the projection room door located at such height that it will be easily operative from the level of the raised deck of the interior of the booth. (b) It would be desirable to install panic bar hardware on the door at the rear of the moving picture theater. This would necessitate re- hanging the door SO that it would swing out into the hallway. 10. FIRE CUT OFFS A. EXECUTIVE MANSION (1) Light Well (Third Floor). - The floor light well in the third floor should be removed and opening floored over with fire-resistive construction. At present it forms an unprotected opening be- tween the second and third floors and at the same time appears not to add materially to the illumi- nation on the second floor. (2) North Portico. - The hollow space between the roof and celotex ceiling in the North Portico is open. This opening would permit fire to gain entrance into this concealed space and spread out of reach of hose streams. Access opening should be closed. (3) Seal up all old and unused ducts to prevent spread of fire, as these passages are out of reach of hose streams and sprinkler water. B. MA.INTENANCE SHOPS (UNDER NORTH PORTICO) (1) Paint Shop. - Cut off the Paint Shop from the Air Raid Tunnel to Treasury by protecting the doorway with a fire door and bricking up open- ings over it. C. EXECUTIVE OFFICE BUILDING (1) Incinerator Room. - The area inside the Inciner- ator Room, immediately adjacent to the sliding metal fire door, must be kept free of materials at all times, otherwise the effectiveness of this fire protection device will be completely nullified. 16 C-69090

Page data

Page
28
Source index
0
Type
photo
Media ID
7ca30985a80650fc
Size
unknown

Document data

ID
354584159
Core
doc
Type
document
DTO data
{
    "id": "354584159",
    "sourceUrl": "https://catalog.archives.gov/id/354584159",
    "contentType": "document",
    "title": "Letter to President Harry S. Truman from John L. Sullivan, with Attachments",
    "citationUrl": "https://catalog.archives.gov/id/354584159",
    "collections": [
        "President's Secretary's Files (Truman Administration)",
        "White House Files"
    ],
    "iiifBase": "https://s3.us-east-1.amazonaws.com/NARAprodstorage/lz/presidential-libraries/truman/hst-psf/602208/976354/976354-01-001.tif",
    "thumbnailUrl": "https://s3.us-east-1.amazonaws.com/NARAprodstorage/lz/presidential-libraries/truman/hst-psf/602208/976354/976354-01-001.tif",
    "largeImageUrl": "https://s3.us-east-1.amazonaws.com/NARAprodstorage/lz/presidential-libraries/truman/hst-psf/602208/976354/976354-01-001.tif",
    "imageCount": 90,
    "hasImages": true,
    "source": "import",
    "hasTranscription": false
}

Context sent to Scholar

Document identity
{
    "localId": "354584159",
    "label": "Letter to President Harry S. Truman from John L. Sullivan, with Attachments",
    "core": "doc",
    "dtoType": "document",
    "citationUrl": "https://catalog.archives.gov/id/354584159"
}
Document source metadata
{
    "id": "354584159",
    "sourceUrl": "https://catalog.archives.gov/id/354584159",
    "contentType": "document",
    "title": "Letter to President Harry S. Truman from John L. Sullivan, with Attachments",
    "citationUrl": "https://catalog.archives.gov/id/354584159",
    "collections": [
        "President's Secretary's Files (Truman Administration)",
        "White House Files"
    ],
    "iiifBase": "https://s3.us-east-1.amazonaws.com/NARAprodstorage/lz/presidential-libraries/truman/hst-psf/602208/976354/976354-01-001.tif",
    "thumbnailUrl": "https://s3.us-east-1.amazonaws.com/NARAprodstorage/lz/presidential-libraries/truman/hst-psf/602208/976354/976354-01-001.tif",
    "largeImageUrl": "https://s3.us-east-1.amazonaws.com/NARAprodstorage/lz/presidential-libraries/truman/hst-psf/602208/976354/976354-01-001.tif",
    "imageCount": 90,
    "hasImages": true,
    "source": "import",
    "hasTranscription": false
}
Document source extras
{
    "url": "https://catalog.archives.gov/id/354584159",
    "naId": 354584159,
    "levelOfDescription": "item",
    "productionDates": [
        {
            "day": 12,
            "logicalDate": "1946-06-12",
            "month": 6,
            "year": 1946
        }
    ],
    "recordType": "description",
    "ocrSource": "nara-archive"
}
Page context
{
    "seq": 28,
    "pageIndex": 0,
    "type": "photo",
    "url": "https://s3.us-east-1.amazonaws.com/NARAprodstorage/lz/presidential-libraries/truman/hst-psf/602208/976354/976354-01-028.tif",
    "mediaId": "7ca30985a80650fc",
    "ocrText": "(1) Motion Picture Theater.\n(a) It would be desirable to provide panic bar\nhardware on the projection room door located at\nsuch height that it will be easily operative from\nthe level of the raised deck of the interior of\nthe booth.\n(b) It would be desirable to install panic bar\nhardware on the door at the rear of the moving\npicture theater. This would necessitate re-\nhanging the door SO that it would swing out\ninto the hallway.\n10. FIRE CUT OFFS\nA. EXECUTIVE MANSION\n(1)\nLight Well (Third Floor). - The floor light well\nin the third floor should be removed and opening\nfloored over with fire-resistive construction.\nAt present it forms an unprotected opening be-\ntween the second and third floors and at the same\ntime appears not to add materially to the illumi-\nnation on the second floor.\n(2) North Portico. - The hollow space between the\nroof and celotex ceiling in the North Portico\nis open. This opening would permit fire to gain\nentrance into this concealed space and spread\nout of reach of hose streams. Access opening\nshould be closed.\n(3) Seal up all old and unused ducts to prevent\nspread of fire, as these passages are out of\nreach of hose streams and sprinkler water.\nB. MA.INTENANCE SHOPS (UNDER NORTH PORTICO)\n(1) Paint Shop. - Cut off the Paint Shop from the\nAir Raid Tunnel to Treasury by protecting the\ndoorway with a fire door and bricking up open-\nings over it.\nC. EXECUTIVE OFFICE BUILDING\n(1) Incinerator Room. - The area inside the Inciner-\nator Room, immediately adjacent to the sliding\nmetal fire door, must be kept free of materials\nat all times, otherwise the effectiveness of\nthis fire protection device will be completely\nnullified.\n16\nC-69090"
}