Ask the Scholar

Page 21 of 22
I can add historical knowledge about this page.

Page image

Page 21

OCR

- 2 - b Since the calibration constant of the Lind electroscope used in these experiments had a value 7 x 10-9, which value we have shown in our statistical analysis to represent the transformation per second of 250 atoms or radon (plus its shortOlived active de- posit) it follows that the transformation of 90 atoms of thoron (plus Th A) should produce an initial drift of the leaf of nearly 0.25 divisions per second. Since the observed drift over the initial period of 54.5 seconds in testing Subject 0 was nearly 0.4 division per second, we see that the observed and expected values have the same order of magnitude. We recognize of course that several other factors enter into the problem, but a more precise analysis will not materially affect the conclusions here presented.

Page data

Page
21
Source index
0
Type
photo
Media ID
8c088989171d87c0
Size
unknown

Document data

ID
75730982
Core
doc
Type
document
DTO data
{
    "id": "75730982",
    "sourceUrl": "https://catalog.archives.gov/id/75730982",
    "contentType": "document",
    "title": "Report, no date",
    "citationUrl": "https://catalog.archives.gov/id/75730982",
    "collections": [
        "Safety Light Collection",
        "Records Related to Radium Dial Painters"
    ],
    "iiifBase": "https://s3.amazonaws.com/NARAprodstorage/lz/electronic-records/SLC/Radium/SLC_0003761_Page_01.jpg",
    "thumbnailUrl": "https://s3.amazonaws.com/NARAprodstorage/lz/electronic-records/SLC/Radium/SLC_0003761_Page_01.jpg",
    "largeImageUrl": "https://s3.amazonaws.com/NARAprodstorage/lz/electronic-records/SLC/Radium/SLC_0003761_Page_01.jpg",
    "imageCount": 22,
    "hasImages": true,
    "source": "import",
    "hasTranscription": false
}

Context sent to Scholar

Document identity
{
    "localId": "75730982",
    "label": "Report, no date",
    "core": "doc",
    "dtoType": "document",
    "citationUrl": "https://catalog.archives.gov/id/75730982"
}
Document source metadata
{
    "id": "75730982",
    "sourceUrl": "https://catalog.archives.gov/id/75730982",
    "contentType": "document",
    "title": "Report, no date",
    "citationUrl": "https://catalog.archives.gov/id/75730982",
    "collections": [
        "Safety Light Collection",
        "Records Related to Radium Dial Painters"
    ],
    "iiifBase": "https://s3.amazonaws.com/NARAprodstorage/lz/electronic-records/SLC/Radium/SLC_0003761_Page_01.jpg",
    "thumbnailUrl": "https://s3.amazonaws.com/NARAprodstorage/lz/electronic-records/SLC/Radium/SLC_0003761_Page_01.jpg",
    "largeImageUrl": "https://s3.amazonaws.com/NARAprodstorage/lz/electronic-records/SLC/Radium/SLC_0003761_Page_01.jpg",
    "imageCount": 22,
    "hasImages": true,
    "source": "import",
    "hasTranscription": false
}
Document source extras
{
    "url": "https://catalog.archives.gov/id/75730982",
    "naId": 75730982,
    "levelOfDescription": "fileUnit",
    "recordType": "description",
    "ocrSource": "nara-archive"
}
Page context
{
    "seq": 21,
    "pageIndex": 0,
    "type": "photo",
    "url": "https://s3.amazonaws.com/NARAprodstorage/lz/electronic-records/SLC/Radium/SLC_0003761_Page_21.jpg",
    "mediaId": "8c088989171d87c0",
    "ocrText": "- 2 -\nb\nSince the calibration constant of the Lind electroscope used in these experiments had\na value 7 x 10-9, which value we have shown in our statistical analysis to represent\nthe transformation per second of 250 atoms or radon (plus its shortOlived active de-\nposit) it follows that the transformation of 90 atoms of thoron (plus Th A) should\nproduce an initial drift of the leaf of nearly 0.25 divisions per second. Since the\nobserved drift over the initial period of 54.5 seconds in testing Subject 0 was nearly\n0.4 division per second, we see that the observed and expected values have the same\norder of magnitude. We recognize of course that several other factors enter into the\nproblem, but a more precise analysis will not materially affect the conclusions here\npresented."
}